Multiline Mechanical Lubricators are used for automatic centralised Lubrication system for Industrial, Marine and similar applications where Lubricant to be used is oil over a vide range of visosity from SAE 20 to SAE 250.
Driven by plant it serves or using its own electric motor with reducation Gear, Lubrite Multiline Mechanical Lubricators provide precise and continuous Lubrication from a Central location. The special feature of this (Brentford Type) system is its unit construction which by allowing various combination of the components, ensures a Lubrication system matched to any particular requirement.
GENERAL DISCRIPTION:
The basic unit comprises a reservoir of appropriate capacity and the required number of pump units with rotatable Banjo outlets. Each pump unit is fitted with a check valve. Lubricators upto 10 pumping units can be supplied with 750 ml and 1.5 ltrs reservoirs and 8 to 20 pump unots with 4 ltrs reservoir. Reservoir capacity is nominal and total capacity includes the pump assembly casting.
Oil livel is indicated through a sight glass on all the models.
PUMP OPERATION:
The pump drive shaft is provided with cams, one for each pair of pup units. These operate rocker arm which move pairea pistons alternately up and down in their respective cylinders. Each pump unit serves one Lubrication line. The drive Shaft can be rotated in either direction. The amount of Lubricant delivered is adjusted by the knurled knobs on top of pump body. The knobs are provided with check nuts to prevent accidental movement.
FLOW INDICATOR ASSEMBLIES: An assembly comprises the Appropriate number of flow Indicators mounted on a suitable Frame. These flow indicators indicate the regularity of delivery and flow in each oil line. Flow indicators are designed to operate oils of viscosity 41 to 173 centistoke at 40 deg C. Heavier oil must not be used.
SPECIFICATIONS: 1. Recommended speed:- Between 10 & 100 rpm.
2. Discharge:- Between ) & .1cc. per pumping unit per stroke.
3. Reservoir capacity: 750 ml, 1.5 ltrs, 4 ltrs.
4. Pressure developed: 1000 psi without flow indicators and 500 psi with flow indicators.
|